Residential wiring, in brief

Background reading. Jeffrey’s current work, as listed on his resume, is commercial. This page does not say he wires houses for a living.

Houses are usually wired in nonmetallic sheathed cable, with a 120/240-volt single-phase service. Commercial buildings are usually conduit or cable assemblies at 480Y/277, with a separate 208Y/120 system for receptacles. The habits do not copy straight across.

  • Device circuits in dwellings have required locations: kitchens, bathrooms, outdoors, garages, and other rooms named in the adopted NEC. GFCI and AFCI protection have grown with each code cycle. The city’s adopted year is the list that matters.
  • Box fill (Article 314) counts conductors, devices, clamps, and grounds. A crowded box is a heat problem and a code problem.
  • A dwelling service disconnect is not permitted to be smaller than 100 amperes under the usual reading of 230.79. Load calculations for a house live in Article 220, and the 2026 NEC reorganized some of that material. Do not quote a volt-per-square-foot number without naming the code year.
  • The neutral and the equipment ground bond at the service, and not at a subpanel. That rule is the same idea as on the grounding page.

The useful crossover from commercial work is the discipline: read the print, support the cable, torque the device, label the panel, and do not work in a live box because it is a house.

Code section numbers, energy-code rules, and utility practices change by edition and by city. The authority having jurisdiction, and the employer’s written program, decide what applies on a given job.